Stationary Type
Particle Counter
- Minimum measurable particle diameter
- 0.1 μm
- Rated flow
- 2.83 L/min
- Maximum particle number concentration
- 10,000 particles/L (coincidence loss 5%)
Particle Counter
- Minimum measurable particle diameter
- 0.08 μm
- Rated flow
- 0.3 L/min
- Maximum particle number concentration
- 100,000 particles/L (coincidence loss 5%)
Particle Counter
- Minimum measurable particle diameter
- 0.1 μm
- Rated flow
- 28.3 L/min
- Maximum particle number concentration
- 2,000,000 particles/m³ (coincidence loss 10%)
Particle Counter
- Minimum measurable particle diameter
- 0.3 μm
- Rated flow
- 0.5 L/min
- Maximum particle number concentration
- 100,000 particles/L (coincidence loss 5%)
Particle Counter
- Minimum measurable particle diameter
- 0.3 μm
- Rated flow
- 3 L/min
- Maximum particle number concentration
- 30,000 particles/L (coincidence loss 5%)
Particle Counter
- Minimum measurable particle diameter
- 10 μm
- Rated flow
- 30 L/min
- Maximum particle number concentration
- 2,000 particles/L (coincidence loss 5%)
Handheld, Battery-operated Type
Particle Counter
- Minimum measurable particle diameter
- 0.3 μm
- Rated flow
- 2.83 L/min
- Maximum particle number concentration
- 140,000,000 particles/m³ (coincidence loss 10%)
Particle Counter
- Minimum measurable particle diameter
- 0.3 μm
- Rated flow
- 2.83 L/min
- Maximum particle number concentration
- 140,000,000 particles/m³ (coincidence loss 10%)
Particle Counter
- Minimum measurable particle diameter
- 0.3 μm
- Rated flow
- 28.3 L/min
- Maximum particle number concentration
- 28,000,000 particles/m³ (coincidence loss 10%)
Particle Counter
- Minimum measurable particle diameter
- 0.3 μm
- Rated flow
- 50 L/min
- Maximum particle number concentration
- 16,000,000 particles/m³ (coincidence loss 10%)
Particle Counter
- Minimum measurable particle diameter
- 1 μm
- Rated flow
- 2.83 L/min
- Maximum particle number concentration
- 45,000 particles/m³ (coincidence loss 10%)
For Pharmaceutical Products
Particle Counter
- Minimum measurable particle diameter
- 0.3 μm
- Rated flow
- 0.5 L/min
- Maximum particle number concentration
- 100,000 particles/L (coincidence loss 5%)
Particle Counter
- Minimum measurable particle diameter
- 0.3 μm
- Rated flow
- 3 L/min
- Maximum particle number concentration
- 30,000 particles/L (coincidence loss 5%)
Particle Counter
- Minimum measurable particle diameter
- 0.3 μm
- Rated flow
- 2.83 L/min
- Maximum particle number concentration
- 140,000,000 particles/m³ (coincidence loss 10%)
Particle Counter
- Minimum measurable particle diameter
- 0.3 μm
- Rated flow
- 2.83 L/min
- Maximum particle number concentration
- 140,000,000 particles/m³ (coincidence loss 10%)
Particle Counter
- Minimum measurable particle diameter
- 0.3 μm
- Rated flow
- 28.3 L/min
- Maximum particle number concentration
- 28,000,000 particles/m³ (coincidence loss 10%)
Particle Counter
- Minimum measurable particle diameter
- 0.3 μm
- Rated flow
- 50 L/min
- Maximum particle number concentration
- 16,000,000 particles/m³ (coincidence loss 10%)
Particle Sensor
- Minimum measurable particle diameter
- 0.5 μm
- Rated flow
- 28.3 L/min
- Maximum particle number concentration
- 28,000,000 particles/m³ (coincidence loss 10%)
Particle Sensor
- Minimum measurable particle diameter
- 0.3 μm
- Rated flow
- 2.83 L/min
- Maximum particle number concentration
- 140,000,000 particles/m³ (coincidence loss 10%)
Particle Sensor
- Minimum measurable particle diameter
- 0.3 μm
- Rated flow
- 2.83 L/min
- Maximum particle number concentration
- 140,000,000 particles/m³ (coincidence loss 10%)
For Multipoint Monitoring
Particle Counter
- Minimum measurable particle diameter
- 0.1 μm
- Rated flow
- 28.3 L/min
- Maximum particle number concentration
- 2,000,000 particles/m³ (coincidence loss 10%)
Particle Sensor
- Minimum measurable particle diameter
- 0.5 μm
- Rated flow
- 28.3 L/min
- Maximum particle number concentration
- 28,000,000 particles/m³ (coincidence loss 10%)
Particle Sensor
- Minimum measurable particle diameter
- 0.3 μm
- Rated flow
- 2.83 L/min
- Maximum particle number concentration
- 140,000,000 particles/m³ (coincidence loss 10%)
Particle Sensor
- Minimum measurable particle diameter
- 0.3 μm
- Rated flow
- 2.83 L/min
- Maximum particle number concentration
- 140,000,000 particles/m³ (coincidence loss 10%)
Particle Sensor
- Minimum measurable particle diameter
- 0.1 μm
- Rated flow
- 2.83 L/min
- Maximum particle number concentration
- 10,000 particles/L (coincidence loss 5%)
For Gas
Particle Sensor
- Minimum measurable particle diameter
- 0.1 μm
- Rated flow
- 100 mL/min
- Maximum particle number concentration
- 30 000 particles/L (coincidence loss 5%)
For Measuring Coarse Particles
Particle Counter
- Minimum measurable particle diameter
- 10 μm
- Rated flow
- 30 L/min
- Maximum particle number concentration
- 2,000 particles/L (coincidence loss 5%)
Particle Counter
- Minimum measurable particle diameter
- 1 μm
- Rated flow
- 2.83 L/min
- Maximum particle number concentration
- 45,000 particles/m³ (coincidence loss 10%)